Search results for "Load cell"

showing 8 items of 8 documents

A preliminary investigation of the effect of contact pressure on the accuracy of heart rate monitoring by wearable PPG wrist band

2019

The increase of safety and health monitor of workers has become a crucial objective to prevent excessive physical workloads, injuries, accidents and errors. Heart rate (HR) is a very important physiological indicator which could properly describe the workers’ physical status. Recently, wearable photoplethysmographic (PPG) wristband trackers have been utilized to measure HR without hindering normal gesture of workers. However, the quality of PPG signals is highly affected by human physical motions, resulting in a poor reliable HR estimation. Specifically, during different activities and gestures, PPG sensor contact pressures may have an impact on the quality of the heart rate signal. To appr…

Computer sciencePhotoplethysmography wearable sensor PPG sensor contact pressureWearable computerSettore ING-IND/34 - Bioingegneria IndustrialeWristSignalLoad cellSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchinemedicine.anatomical_structureHeart rate monitoringHeart ratemedicineSettore ING-IND/12 - Misure Meccaniche E TermicheHeart rate variabilitysense organsContact pressureBiomedical engineering
researchProduct

A Laboratory Scale Equipment to Relieve Force and Pressure in Cold Extrusion of Lead Hollow Components

2008

Nowadays, many researchers are involved in studies aimed to the explanation of some peculiar aspects regarding manufacturing processes. In this paper, an experimental campaign was carried out in order to reproduce tube extrusion starting from a cylindrical billet. In particular, the development of a proper equipment is presented: the aim was to measure both the total load, by using the testing machine load cell, and the local pressure value on the porthole. The latter task was carried out performing a proper system based on the use of a small load-cell. The tube was extruded with a good surface quality and the external area does not show any welding line evidence. Pure Lead was used for the…

EngineeringComputer simulationbusiness.industryExtrusionMechanical EngineeringMechanical engineeringWeldingCompression (physics)Load celllaw.inventionPressure measurementMechanics of MaterialslawGeneral Materials ScienceExtrusionTube (container)pressure measurementbusinessDuctilitySettore ING-IND/16 - Tecnologie E Sistemi Di Lavorazione
researchProduct

The harp: a vehicle crash test apparatus for full-scale crash test experiments

2012

Published version of an article in the journal: The International Journal of Advanced Manufacturing Technology. Also available from the publisher at: http://dx.doi.org/10.1007/s00170-012-3960-3 The current paper describes an apparatus for full-scale vehicle crash test experimentation. This apparatus is referred to as the harp. In brief, the harp may either accelerate a trolley which is impacted into a test vehicle or the test vehicle itself may be accelerated and impacted into an object such as a barrier, a pole, or another vehicle. If a trolley is accelerated, it is equipped with load cells to record the axial crushing force. If a test vehicle is accelerated, it is equipped with a three-ax…

Engineeringthe harpstructural componentsbusiness.industryMechanical EngineeringInstrumentationimpact testingFull scaleMechanical engineeringCrashAccelerometerLoad cellCrash testIndustrial and Manufacturing EngineeringAutomotive engineeringComputer Science ApplicationsTest (assessment)Control and Systems EngineeringVDP::Technology: 500::Materials science and engineering: 520businessSoftwarekicking machineHARP
researchProduct

Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs

2013

NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic retransformation during the unloading. The temperature variations induced changes in the spring force. Objectives: The aim of this study is to investigate the effect of the temperature variations in the spring forces and corrosion behaviour simulating the ingestion hot/cold drinks and food. Study D esign: The springs were subjected to a tensile force using universal testing machine MTS-Adamel (100 N load cell). All tests were performed in artificial saliva maintained at different t…

Materials scienceElasticidadOrtodòncia616.3OdontologíaOrthodontics:Enginyeria dels materials [Àrees temàtiques de la UPC]Load cellNiTiCorrosionPhysical PhenomenaStress (mechanics)RecoveryMaterials TestingBiomaterials and Bioengineering in DentistryOrthodontic WiresOrthodonticComposite materialSuperelasticitySalivaGeneral DentistryUniversal testing machineElasticitatTemperatureNíquel-titani -- AliatgesCoilsTemperatura:CIENCIAS MÉDICAS [UNESCO]Coil springCiencias de la saludElasticityOrtodonciaNickel-titanium alloysSpringsOtorhinolaryngologySpring (device)Nickel titaniumPseudoelasticityUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgery
researchProduct

Mechanical properties of the NiTi Memoria Leaf Spring Activated Expander (NiTi MLSAE) for maxillary transverse discrepancy correction: An in-vitro st…

2020

Background To determine the mechanical properties of the NiTi Memoria® Leaf Spring Activated Expander (NiTi MLSAE) in two forms, unaltered (unbent) and altered (bent) to mimic clinical use. Material and Methods This in-vitro pilot study was conducted using eight NiTi MLSAE expanders (American Tooth Industries, Oxnard, California) representing four force magnitudes: 10mm 500g, 10mm 900g, 6mm 450g and 6mm 900g models. Two experiments were performed: the first tested the expanders in their unbent form and the second tested them after they were bent by one experienced technician. All expanders were adapted to a standard three dimensional printed maxillary study model. A Dillion Quantrol 500N (1…

OrthodonticsMaterials scienceBent molecular geometry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]Posterior crossbite01 natural sciencesLoad cellTransverse plane020303 mechanical engineering & transports0203 mechanical engineeringLeaf springNickel titaniumUNESCO::CIENCIAS MÉDICAS0103 physical sciencesIn vitro study010301 acousticsGeneral DentistryExpansiveJournal of Clinical and Experimental Dentistry
researchProduct

A Study on the Measurement Instrumentation for a Custom-Made Bipendulum Impact Testing Machine

2008

Experimental investigations of structures under impact loads are normally carried out by means of drop-weight testing rigs, which are often tailor made, and require sensors for fast transient measurement of mechanical quantities (namely, force, displacement, velocity, and absorbed energy). Since these tests are quite expensive, time consuming, and, often, not repeatable, the sensors must provide reliable and interpretable results in the first trial. In this paper, a thorough study on the measurement instrumentation suitable to carry out reliable low-velocity impact tests by means of a custom-made bipendulum impact testing machine is presented. Attention has been focused on the choice of the…

Piezoelectric transducersComputer scienceImpact measurements; Instrumented impact testing; Optical velocity sensors; PVDF force sensors; Piezoelectric transducers; Transient measurementsImpact measurementsMechanical engineeringAccelerometerLoad cellFriction lossDynamic load testingTransducerOptical velocity sensorsElectronic engineeringCalibrationPVDF force sensorsTransient measurementsInstrumentation (computer programming)Electrical and Electronic EngineeringImpactInstrumentationInstrumented impact testing
researchProduct

Evaluation of the force generated by gradual deflection of 0.016-inch NiTi and stainless steel orthodontic wires in self-ligating metallic and esthet…

2019

Background The purpose of this study was to evaluate the deflection forces of 0.016-inch Nitinol and stainless steel orthodontic wires, in association to different self-ligating brackets. Material and Methods Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10N load cell and ISO 15,841, as a protocol. Eight of these models were prepared, each one for the bonding of each set of self-ligating accessories to be tested: Damon Q, Damon Clear (Ormco), In-Ovation R, In-Ovation C (GAC), BioQuick, QuickClear (Forestadent), SmartClip and Clarity SL (3M). Data were subjected to One-way ANOVA, followed by Tukey tests (P<0.05). Re…

TITÂNIOUniversal testing machineMaterials scienceOrthodontic wireResearchOrthodontics:CIENCIAS MÉDICAS [UNESCO]Load cellDeflection (engineering)Nickel titaniumUNESCO::CIENCIAS MÉDICASComposite materialGradual increaseGeneral Dentistry
researchProduct

Similar biomechanical properties of four tripled tendon graft models for ACL reconstruction

2021

Abstract Purpose The present study tested and compared the biomechanical properties of four different triplicate graft tendon techniques. Methods 32 tripled tendons from the common extensor muscle of bovine fingers were tested on a material testing machine, passing the end loop over a metal rod of a clevis connected to the load cell on the upper side, and fixing the lower end to a clamp. The samples were divided into four groups: (A) tripled with a free end sutured only to one of the two fixed bundles (B) tripled with a free end positioned between the two fixed strands and sutured to both (C) tripled with an S-shape and all the three strands sutured together at the upper and lower extremiti…

medicine.medical_specialtyLoad cellTendonsGraftLoad to failureMaterials TestingMedicineAnimalsHumansOrthopedics and Sports MedicineAnterior Cruciate LigamentTendon graftOrthodonticsAnterior Cruciate Ligament Reconstructionbusiness.industryKnee biomechanicsSignificant differenceTripled graftBiomechanicsGeneral MedicineTendonBiomechanical PhenomenaACL reconstructionmedicine.anatomical_structureClampOrthopedic surgerySurgeryCattleGraft diameterbusinessTriplicate
researchProduct